Gas Liner®

Reline APTEC GmbH GT/002/0617 UNDER REVIEW
Expires 20/06/22 

Scope

To assess the performance of the GasLiner® UV light cured liner system as supplied by Reline APTEC GmbH for replacement of cast iron and steel gas distribution mains with diameters between 150mm and 1220mm.

Product Description

The system comprises of a glass fibre reinforcement woven sleeve, including a specially designed and unique seamless thermoplastic interior coating, which is factory impregnated with an ultra violet (UV) light curing polyester or vinyl ester thermosetting resin. When installed and cured, this forms a full-length cured-in-place structural liner within the host pipe.

The liner is applicable to gas distribution systems up to 2 bar operating pressure in Great Britain. It is not applicable to service and end fitting connections.

Full details can be found in the Assessment Schedule.

Click here to enlarge certificate.

Created by potrace 1.16, written by Peter Selinger 2001-2019

Start a conversation

Full name
Email address
Company name
How can we help?

Can we stay in touch?

Your details will be stored within our CRM to allow us to handle your enquiry. We'd love to keep in touch and send you our newsletters and other notifications we think may be of interest to you. Please let us know if we have your permission for this.

Full name
Company name
Email address
Phone number

Can we stay in touch?

Your details will be stored within our CRM to allow us to handle your enquiry. We'd love to keep in touch and send you our newsletters and other notifications we think may be of interest to you. Please let us know if we have your permission for this.