Leak Tightness Testing to WIS 4-34-07

Specification for Leak Tightness Testing of Cured-in-Place-Pipe Lining Systems for Gravity Sewer Rehabilitation


Proven Confidence for CIPP Systems

Following a collaborative project led by WRc with six UK water companies, the Government of Jersey, and eight CIPP suppliers, WIS 4-34-07 Specification for Leak Tightness Testing of CIPP Lining Systems has now been published. This specification gives the water industry a consistent, reliable way to assess leak tightness and identify products that help reduce groundwater infiltration into already stretched sewer networks. With growing regulatory pressure and AMP8 investment focused on cutting sewer spills and improving network resilience, independent performance testing is increasingly essential. 

As a key contributor to the development of the method, WRc now offers leak tightness testing for CIPP systems, end seals, and connection collars in accordance with WIS 4-34-07, giving manufacturers verified performance data and helping clients specify solutions with confidence.

Testing Certificates

For product queries, please contact the certificate holder directly.

Filter / Search
Showing “All certifications (A-Z)”
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Sorry, there are no matches beginning with the letter ''.

GL16 Reinforced Fibreglass Lining System

Impreg (UK) Ltd

Ref: TS/020/0125

Certificate

Inpipe UV CIPP Full Length GFRP Liner System

Inpipe Sweden AB

Ref: TS/024/0325

Certificate

Inpipe UV CIPP Full-Length GFRP Liner System with Cosmic Top Hat

Inpipe Sweden AB

Ref: TS/025/0325

Certificate

LatWrap Lining System

Lateral Repairs UAB

Ref: TS/017/0325

Certificate

Novapipe

Applied Felts

Ref: TS/023/1024

Certificate

Premier Pipe+ Lining System

Onsite Central Limited

Ref: TS/019/0525

Certificate

RSM Hot Cure Leak Tight (LT) Epoxy Lining System

RSM Linings Supplies Global Ltd

Ref: TS/018/0325

Certificate

SAERTEX-LINER®

Saertex multiCom GmbH

Ref: TS/021/0125

Certificate

Trelleborg Drainliner Method Liner

Trelleborg Sealing Profiles GmbH

Ref: TS/016/0925

Certificate

Vortex Quad-Cure

Vortex Lining Division Ltd

Ref: TS/022/1124

Certificate

Get Tested

Want your product tested in accordance with the WIS 4-34-07 Leak Tightness Specification?

We'd be delighted to hear from manufacturers looking for further information on the requirements and test procedures or to book your testing date.

Get in touch to start your WIS testing journey. 

Contact Us
The work undertaken by WRc to devise the CP655 infiltration testing method for cured-in-place pipe materials has been pivotal in setting a new industry standard. This approach provides consistency across the water sector, ensuring sewer assets are structurally enhanced while confidently mitigating groundwater infiltration. Throughout the process, the project liaison group has been fully engaged and has constructively contributed to shaping the outcomes. As a result, the bar has been raised across the supply chain, with a growing number of suppliers now achieving approval status against the CP655 criteria – a milestone that reflects real progress for our industry.

Scott Weston
IMR Water Recycling Alliance

Created by potrace 1.16, written by Peter Selinger 2001-2019
Find out more about WIS 4-34-07 Leak Tightness Testing
Full name
Email address
Company name
How can we help?

Can we stay in touch?

Your details will be stored within our CRM to allow us to handle your enquiry. We'd love to keep in touch and send you our newsletters and other notifications we think may be of interest to you. Please let us know if we have your permission for this.

Full name
Company name
Email address
Phone number

Can we stay in touch?

Your details will be stored within our CRM to allow us to handle your enquiry. We'd love to keep in touch and send you our newsletters and other notifications we think may be of interest to you. Please let us know if we have your permission for this.

Filters: